ANNEX 2 - CONDITIONS CONSISTENT WITH THE OPERATING SCHEDULE
General
To liaise and comply with all the relevant authorities.
To continue to develop and improve the operating schedules that are in place.
The prevention of crime and disorder
CD5
The Designated Premises Supervisor, when present, and all members of staff shall ensure that all lawful instructions and/or directions given by the Police are complied with.
CD9
No person in possession of a drink in a sealed or unsealed container shall be allowed to enter the premises except for the purposes of delivery.
CD10
No drink shall be sold from a bar or by staff service or consumed in or on the premises other than in a container made from non-splintering plastic, paper or shatterproof glass. (Your attention is drawn to the requirements of the Weights and Measures Act 1985).
CD11
No drink shall be removed from the premises in an unsealed container.
CD17
The maximum number of persons allowed in these premises shall be normal operating numbers - 90 maximum, occasional marquee wedding in garden (1 or 2 a year) - 150 maximum.
CD18
There shall be in place for the premises a written admissions policy to prevent the sale or supply of alcohol to persons under 18 years of age. That policy shall require any person who appears to be under the age of 18 years to produce a recognised proof of age card accredited under the Proof of Age Standards Scheme (PASS), a citizen card supported by the Home Office, a photo driving licence, a passport or official HM Forces or EU ID card bearing photo and date of birth.
CD19
A notice or notices shall be displayed in and at the entrance to the premises where they can be clearly seen and read and shall indicate that it is unlawful for persons under 18 to purchase alcohol or for any person to purchase alcohol on behalf of a person under 18 years of age.
CD22
There shall be displayed at the entrance to the premises a sign, which is clearly visible to members of the public visiting those premises containing details of the trading hours under the premises licence, the licensable activities permitted on those premises and any maximum occupancy level set for the premises. (See also CD17).
Public safety
PS1
When disabled persons are present on the premises there shall be in place arrangements for their safe evacuation in the case of an emergency or other reason. Details of those arrangements shall be recorded in writing and all staff employed on the premises shall be aware of those arrangements.
PS2
All disabled persons on the premises shall be made aware of the evacuation arrangements.
PS3
All parts of the premises shall at all times be kept free from defect and no changes, alterations of any kind to the surface finish or coverings including furniture and flooring on any part of the premises shall be made without the prior approval of the Council.
PS6
All exits and escape routes to those exits (including external escape routes) from the premises shall be provided with slip resistant even surfaces and shall be maintained in good repair, correct working order and kept free from all obstructions when the public are on the premises. External escape routes shall also be kept free from ice and snow.
PS8
All doors or gates both inside and outside the premises which are on an escape route shall be fitted only with approved fasteners and shall at all times be properly maintained, free from obstruction and be capable of being opened easily and fully so that they do not restrict the public leaving the premises and shall open in the direction of the escape route.
PS10
All exit doors and gates from premises or enclosure(s) surrounding it shall be capable of being opened by any person without the use of a key, card, code or other similar means and be kept free from all fastening devices when the premises are open to the public.
PS11
All exit routes and doors on such routes shall be checked on every occasion before the premises is used for purposes of a licensable activity and at regular occasions when the premises are open to the public to ensure that they are free from defect, obstruction, trip hazards and surfaces are not slippery. A record of such inspections, any defects discovered and the remedial action taken shall be made in writing in a logbook kept for that purpose. That logbook shall be made available for inspection on demand to an Authorised Officer of the Council, a Fire Officer or a Police Constable.
PS12
The method of opening any exit door or gate from the premises or enclosure(s) surrounding it shall be clearly displayed immediately above or below the fastening in white block lettering on a green background in letters not less than 50 mm high.
PS14
Where a fire-resisting door is fitted within the premises and that door is required to be kept closed at all times then the door shall be clearly marked on both sides with a sign bearing the words "FIRE DOOR KEEP CLOSED" in block letters not less than 50mm high and clearly visible when the premises are open to the public.
PS16
Any door or gate in the premises which is not an exit door or gate shall have a sign bearing the word "PRIVATE" in block letters not less than 50 mm high.
PS18
The furniture or seating in premises shall be arranged so that it does not obstruct any exit, route to any exit or to any facility within the premises.
PS20
Before the premises are opened for the purposes authorised by the licence an inspection shall be carried out to ensure that the premises are safe for use. Details of the inspection, defects discovered and remedial action taken shall be recorded in writing in a logbook kept for that purpose. That logbook shall be made available for inspection on demand to an Authorised Officer of the Council, a Fire Officer or a Police Constable.
PS21
The premises shall be maintained so that the following fire retardancy standards are complied with:
(i) All upholstered seating meets on a continuous basis the pass criteria for smouldering ignition source 1 and crib ignition source 5 when tested in accordance with section 5 of BS 5852:1990.
(ii) All repairs or refurbishment of existing seating or upholstery shall include the removal of untreated polyurethane foam and its replacement by fillings which conform to the Furniture and Furnishings (Safety) Regulations 1988 (as amended).
(iii) Carpets - B.S.4790 low radius of spread.
(iv) Walls and Ceilings - Circulation areas, Building Regulations. Class O General Areas, B.S.476 Class1.
(v) All artificial foliage, floral decorations or any other decoration provided on the premises shall be of inherently flameproof material.
PS23
No curtain, hanging or any other decoration shall be positioned so as to obstruct any exit, sign or fire fighting equipment. Curtains covering doorways should be divided down the middle and so hung that the lower edge of the curtain does not touch the floor. They should not obstruct notices, exit signs, fire fighting equipment etc.
PS24
At all times when the premises are used for the purpose of the licence, the licence holder, manager or designated premises supervisor who is responsible for the management of the premises shall at all times be aware of the number of persons on the premises and shall if requested to do so give that information to an Authorised Officer of the Council, a Fire Officer or a Police Constable. (See also CD17)
PS25
Printed notices shall be prominently displayed in the premises detailing the essential steps that must be taken if a fire is discovered or the fire alarm goes off or other emergency arises and how to call the Fire Service.
PS26
A person who is nominated for the purpose of taking control in the event of a fire, fire alarm, emergency or event which may effect the safety of persons attending the premises shall be on and in charge of the premises at all times when any licensable activity is being provided.
That person shall be responsible for calling the Fire Service in the event of any fire and that person shall also be responsible for meeting the Fire Service and advising them of the location of the fire.
PS27
Any outbreak of fire of any kind shall be reported to the Fire Service immediately and a written record shall be made in a logbook kept for that purpose.
PS29
Clear and unobstructed access shall be available to the premises for use by the emergency services and emergency service vehicles at all times.
PS30
There shall be maintained on the premises at all times an adequate and appropriate supply of first aid equipment and materials.
PS32
When the public, members or guests are present, the lighting levels in all parts of the premisesshall be capable of providing sufficient illumination for the public, members or guests to leave the premises safely and there shall be at least one person who is nominated to switch on the house lights in an emergency situation.
PS33
All fire instruction signs shall be illuminated so that they can be easily read at all times when the public, members or guests are present on the premises.
PS35
Every battery which is used to power an emergency light or exit sign shall be maintained in a fully charged condition at all times.
PS36
On every occasion before the public, members or guests are admitted to the premises an inspection of all normal and emergency lighting shall take place. A record shall be kept in a logbook of those tests and any faults discovered together with a record of the work carried out to repair those faults. All faults discovered shall be repaired immediately or if that cannot be done then as soon as is possible and the reason for the delay shall be entered in the logbook.
(See also PS71)
PS37
No temporary electrical wiring or distribution system shall be installed in the premises unless, the installation is carried out by a suitably qualified and competent person. The premises licence holder or Club Premises Certificate holder shall obtain a certificate from that person that the installation is fit for purpose and complies with British Standard 7671 and where applicable, British Standard 7909. A copy of that certificate shall be produced by the Premises Licence Holder or the Club Premises Certificate Holder if requested to do so by an Authorised officer of the Council or an Officer of the Cumbria Fire and Rescue Service.
PS38
Where any temporary electrical wiring or distribution system has been installed in any premises by a person who is not competent to do so, the premises licence holder or Club Premises Certificate holder installation shall have the installation inspected and certified in writing by a suitably qualified and competent person that it is fit for purpose and complies with British Standard 7671 and where applicable, British Standard 7909. A copy of that certificate shall be produced by the Premises Licence Holder or the Club Premises Certificate Holder if requested to do so by an Authorised officer of the Council or an Officer of the Cumbria Fire and Rescue Service.
PS39
A written notice has been served on the Council not less than ten days before any work commences unless this is not possible due to time constraints. In such cases written notice shall be served as soon as is practicable.
PS40
The premises shall be provided with adequate and accessible lavatory accommodation which shall at all times when the premises are in use be kept clean, ventilated, disinfected and supplied with hot and cold water, soap, toilet tissue, hand drying and sanitary towel disposal facilities as appropriate.
PS71
Emergency Lighting will be tested in accordance with BS 5266 Part 1, 1999 Emergency Lighting. The results of the tests will be recorded in a logbook. A satisfactory NICEIC (or equivalent) inspection report will be provided annually to the Licensing Authority.
PS72
The fire alarm detection system will be tested in accordance with BS 5839 Part 1 2002 Fire Detection and Fire Alarm Systems for buildings. The results of the tests will be recorded in a log book. A satisfactory inspection report will be provided annually to the Licensing Authority.
PS73
The electrical installation will be inspected and a satisfactory NICEIC (or equivalent) inspection report will be provided annually to the Licensing Authority.
PS74
Any gas boiler, calorifier or other gas appliance will be tested on a regular basis and a satisfactory CORGI (or equivalent) inspection report will be provided annually to the Licensing Authority.
PS76
Fire fighting equipment shall be provided throughout the premises at suitable locations and be appropriate to the risk to comply with BS 5306 Part 8, Selection and Installation of Portable Fire Extinguishers.
PS77
The extinguishers shall be hung on a wall bracket with the handle or carrying device approximately 1.1 metres from the floor.
PS78
Firefighting equipment shall be examined regularly by the manufacturer or other competent person and maintained and tested in accordance with BS 5306 Part 3, 2000.
PS79
All members of staff will be familiar with the operation of the firefighting equipment.
PS80
All staff shall be instructed and trained to ensure that they understand the fire precaution measures in the building and the procedure and action to be taken in the event of fire.
PS81
Practice fire drills shall be carried out at least once per year or at such additional times as required to train new staff. A competent person will conduct the drills by operating the fire alarm so that staff can rehearse their specific task or duties.
PS 82
All training and instruction shall be recorded in a log book.
PS83
A ventilation system will be provided and suitably maintained to deliver fresh air and extract contaminated air away from staff and customers.
The prevention of public nuisance
PPN1
The licensed premises or the parts of the licensed premises edged in red on the attached plan of the premises may be open to the public between the hours permitted by this licence.
PPN3
No nuisance shall be caused by noise coming from the premises or by vibration transmitted through the structure of the premises.
PPN4
All external doors and windows shall be kept closed when regulated entertainment is being provided except in the event of an emergency.
PPN5
The noise level from the premises whilst being used for public entertainments purposes, shall not cause nuisance to noise sensitive dwellings in the vicinity.
PPN8
Refuse such as bottles shall be disposed of from the premises at a time when it is not likely to cause a disturbance to residents in the vicinity of the premises.
PPN9
There shall be no emission from the premises of any offensive smells, which are likely to cause a nuisance.
PPN10
Where there are any offensive smells created on the premises, provision shall be made for such smells to be vented from the premises so that they do not cause a nuisance to nearby premises.
PPN11
There shall be provided at the premises containers for the storage and disposal of waste foods and other refuse from the premises. Those containers shall be constructed, maintained and located so that access to them by vermin and unauthorised persons is prevented and arrangements shall be made for the regular lawful disposal of their contents.
PPN12
Where the premises provide food to the public for consumption on or off the premises there shall be provided at or near the exits, sufficient waste bins to enable the disposal of waste food, food containers, wrappings etc.
PPN13
Where the premises provide food for consumption off the premises, the public area immediately surrounding the premises shall be cleared of waste food, food containers, wrapping etc. at the end of trading on each day. Such refuse shall be placed in a container designed for the storage and disposal of refuse and waste foods which shall be constructed, maintained and located so that access to it by vermin and unauthorised persons is prevented and arrangements shall be made for the regular lawful disposal of their contents.
PPN14
No light from or on the premises and any other light under the control of the premises shall be provided where that light causes a nuisance to any nearby premises.
The protection of children from harm
PCH 2
Children under the age of 18 years are not permitted on the premises during opening hours without being accompanied by an adult.