ANNEX 2 - CONDITIONS CONSISTENT WITH THE OPERATING SCHEDULE
Prevention of Crime and Disorder
CD17
The maximum number of persons allowed in these premises shall be 200.
CD19
A notice or notices shall be displayed in and at the entrance to the premises where they can be clearly seen and read and shall indicate that it is unlawful for persons under 18 to purchase alcohol or for any person to purchase alcohol on behalf of a person under 18 years of age.
PS1
When disabled persons are present on the premises there shall be in place arrangements for their safe evacuation in the case of an emergency or other reason. Details of those arrangements shall be recorded in writing and all staff employed on the premises shall be aware of those arrangements.
PS6
All exits and escape routes to those exits (including external escape routes) from the premises shall be provided with slip resistant even surfaces and shall be maintained in good repair, correct working order and kept free from all obstructions when the public are on the premises. External escape routes shall also be kept free from ice and snow.
PS10
All exit doors and gates from premises or enclosure(s) surrounding it shall be capable of being opened by any person without the use of a key, card, code or other similar means and be kept free from all fastening devices when the premises are open to the public.
PS18
The furniture or seating in premises shall be arranged so that it does not obstruct any exit, route to any exit or to any facility within the premises.
PS19
Where seats are arranged for a closely seated audience, the seating and gangways shall be fixed and arranged to allow free unobstructed access to exits, routes to exits and the facilities provided in the premises.
PS21
The premises shall be maintained so that the following fire retardancy standards are complied with:
() All upholstered seating meets on a continuous basis the pass criteria for smouldering ignition source 1 and crib ignition source 5 when tested in accordance with section 5 of BS 5852:1990.
() All repairs or refurbishment of existing seating or upholstery shall include the removal of untreated polyurethane foam and its replacement by fillings which conform to the Furniture and Furnishings (Safety) Regulations 1988 (as amended).
() Carpets - B.S.4790 low radius of spread.
() Walls and Ceilings - Circulation areas, Building Regulations. Class O General Areas, B.S.476 Class1.
(v) All artificial foliage, floral decorations or any other decoration provided on the premises shall be of inherently flameproof material.
PS25
Printed notices shall be prominently displayed in the premises detailing the essential steps that must be taken if a fire is discovered or the fire alarm goes off or other emergency arises and how to call the Fire Service.
PS29
Clear and unobstructed access shall be available to the premises for use by the emergency services and emergency service vehicles at all times.
PS30
There shall be maintained on the premises at all times an adequate and appropriate supply of first aid equipment and materials.
PS33
All fire instruction signs shall be illuminated so that they can be easily read at all times when the public, members or guests are present on the premises.
PS35
Every battery which is used to power an emergency light or exit sign shall be maintained in a fully charged condition at all times.
PS40
The premises shall be provided with adequate and accessible lavatory accommodation which shall at all times when the premises are in use be kept clean, ventilated, disinfected and supplied with hot and cold water, soap, toilet tissue, hand drying and sanitary towel disposal facilities as appropriate.
PS54
In no circumstances shall any person be allowed to:
(a) sit in any gangway
(b) stand or sit in front of any exit; or
(c) stand or sit on any staircase including any landing
PS62
Where the audience is seated around tables, the seating need not be fixed but both tables and chairs shall be arranged so that gangways are clearly identifiable and unobstructed.
PS71
Emergency Lighting will be tested in accordance with BS 5266 Part 1, 1999 Emergency Lighting. The results of the tests will be recorded in a logbook. A satisfactory NICEIC (or equivalent) inspection report will be provided annually* to the Licensing Authority.
PS73
The electrical installation will be inspected and a satisfactory NICEIC (or equivalent) inspection report will be provided annually* to the Licensing Authority.
PS76
Fire fighting equipment shall be provided throughout the premises at suitable locations and be appropriate to the risk to comply with BS 5306 Part 8, Selection and Installation of Portable Fire Extinguishers.
PS77
The extinguishers shall be hung on a wall bracket with the handle or carrying device approximately 1.1 metres from the floor.
PS78
Firefighting equipment shall be examined regularly by the manufacturer or other competent person and maintained and tested in accordance with BS 5306 Part 3, 2000.
PS81
Practice fire drills shall be carried out at least once per year or at such additional times as required to train new staff. A competent person will conduct the drills by operating the fire alarm so that staff can rehearse their specific task or duties.
Prevention of Public Nuisance
PPN3
No nuisance shall be caused by noise coming from the premises or by vibration transmitted through the structure of the premises.
PPN4
All external doors and windows shall be kept closed when regulated entertainment is being provided except in the event of an emergency.
PPN6
The licence holder or his representative shall conduct regular assessments of the noise coming from the premises on every occasion the premises are used for regulated entertainment and shall take steps to reduce the level of noise where it is likely to cause a disturbance to local residents. A written record shall be made of those assessments in a log book kept for that purpose and shall include, the time and date of the checks, the person making them and the results including any remedial action.
PPN8
Refuse such as bottles shall be disposed of from the premises at a time when it is not likely to cause a disturbance to residents in the vicinity of the premises.
PPN10
Where there are any offensive smells created on the premises, provision shall be made for such smells to be vented from the premises so that they do not cause a nuisance to nearby premises.
PPN13
Where the premises provide food for consumption off the premises, the public area immediately surrounding the premises shall be cleared of waste food, food containers, wrapping etc. at the end of trading on each day. Such refuse shall be placed in a container designed for the storage and disposal of refuse and waste foods which shall be constructed, maintained and located so that access to it by vermin and unauthorised persons is prevented and arrangements shall be made for the regular lawful disposal of their contents.
No nuisance
Protection of Children from Harm
PCH 3
No person under the age of (specify age) shall be permitted on the premises between the hours of (specify hours, days).
PCH 4
The admission of children to a film exhibition shall be restricted in accordance with Section 20 of the Licensing Act 2003.
PCH14
Where any premises are to be used for any performance which includes the participation of children, such children shall at all times when they are on the premises remain under the supervision of an adult